Observational Study of Bicuspid Aortic Valve Competence
This observational study is looking at people with a bicuspid aortic valve (BAV), a common heart condition where the aortic valve has two flaps instead of the usual three. The study uses 4D CTA imaging (a type of CT scan that shows movement) to better understand the normal anatomy of these valves when they are working well. You may be able to join if you are at least 18 years old, have a documented BAV with minimal calcification, and sign a consent form. The study aims to measure the size and shape of the valve's parts over time to help doctors improve BAV repair surgeries. The current recruitment status is unclear.
- Study design
- This is an observational study with a planned enrollment of 60 participants. It is not specified if it is randomized or blinded.
- What's involved
- You would undergo annual 4D CTA scans, routine echocardiograms, and history and physical assessments for five years.
- Compensation
- Not stated in the trial record.
- Follow-up
- Your cusp surface areas, cusp height, and cusp free margin length will be measured through study completion, an average of one year.
AI-generated from the public study record. Only the study team can confirm whether you're eligible — confirm details with them before making decisions.
Prospective 4D CTA of BAV Competence
At a glance
Conditions
Where it's being run
1 sites across 1 statesWho to contact
Opens a ready-to-send draft in your own email app — review before sending.
Do you actually qualify for this trial?
Add a private profile and we'll compare every criterion below against your situation — and tell you which ones are met, uncertain, or excluding.
Inclusion
Exclusion
What this trial measures
- Cusp surface areas over the cardiac cycleThrough study completion, an average of 1 year
Surface area of each cusp in mm2 in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Cusp height (geometric and effective)Through study completion, an average of 1 year
Geometric and effective cusp height in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Cusp free margin lengthThrough study completion, an average of 1 year
Length of the free margin of each cusp in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Cusp thickness (including raphe thickness, if applicable)Through study completion, an average of 1 year
Thickness of each cusp in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Commissural heightThrough study completion, an average of 1 year
Height of each commissure in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Sino tubular junction sizeThrough study completion, an average of 1 year
Diameter of the sinotubular junction in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Size of the sinuses of ValsalvaThrough study completion, an average of 1 year
Maximum diameter of the sinuses of Valsalva (mid-level of the aortic root) in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Ventriculoaortic junction sizeThrough study completion, an average of 1 year
Diameter of the ventriculoaortic junction in mm in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Aortic annulus sizeThrough study completion, an average of 1 year
Diameter of the aortic cusp in mm measured in one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Coaptation height at diastoleThrough study completion, an average of 1 year
Length of the coaptation zone of the cusps in mm when the valve is closed. This measurement is made in one cardiac cycle (\~0.6 - 1s in length) from the CT image.
- Cusp displacement over the cardiac cycleThrough study completion, an average of 1 year
Total displacement of the center of the free margin of each cusp in mm during one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Cusp velocity over the cardiac cycleThrough study completion, an average of 1 year
Maximum velocity of the center of the free margin of each cusp in mm/s during one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.
- Size of the ascending aortaThrough study completion, an average of 1 year
Maximum diameter of the ascending aorta in cm during one cardiac cycle (\~0.6 - 1s in length). This measurement is made directly from the CT image.