Ultralow Dose PET Imaging for Neuroendocrine Tumors
This study is testing a new way to use PET imaging to find and monitor neuroendocrine tumors. It uses a very small amount of a radioactive tracer called 68Ga-Dotatate, which attaches to a protein (SSTR2) often found on these tumors. The goal is to see if this "ultralow dose" imaging can create clear pictures while using 10 to 100 times less radiation than standard methods. This could make imaging safer and more frequent. Researchers will inject you with 68Ga-Dotatate and then image you on a special PET scanner for up to 3 hours. The study aims to enroll about 200 people, including healthy volunteers and those with neuroendocrine tumors, to see how well this technique works. The study status is currently unclear.
- Study design
- This is an interventional study planning to enroll 200 participants, including healthy controls and individuals with neuroendocrine tumors.
- What's involved
- Participants will be injected with 68Ga-Dotatate and then undergo PET imaging for up to 3 hours.
- Compensation
- Not stated in the trial record.
- Follow-up
- The primary outcomes will be evaluated annually based on pooled images acquired during the preceding 12-month period.
AI-generated from the public study record. Only the study team can confirm whether you're eligible — confirm details with them before making decisions.
Ultralow Dose PET Imaging of SSTR2 Radiotracer Uptake
At a glance
Conditions
Where it's being run
1 sites across 1 statesWho to contact
Opens a ready-to-send draft in your own email app — review before sending.
Do you actually qualify for this trial?
Add a private profile and we'll compare every criterion below against your situation — and tell you which ones are met, uncertain, or excluding.
Inclusion
Exclusion
What this trial measures
- Signal-to-Noise Ratio (SNR)Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Measurement of signal-to-noise ratio for image quality assessment across different scan durations, reconstruction techniques, and artificial intelligence (AI)-enhanced image reconstructions. Unit of Measure: SNR (unitless, numeric ratio)
- Contrast-to-Noise Ratio (CNR)Time Frame: Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Measurement of contrast-to-noise ratio for image quality assessment across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: CNR (unitless, numeric ratio)
- Coefficient of Variation (COV)Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Measurement of the coefficient of variation in selected regions for evaluating image consistency across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: Percentage (%)
- Spatial Resolution (Full Width at Half Maximum - FWHM)Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Assessment of spatial resolution using full width at half maximum (FWHM) across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: Millimeters (mm)
- Target-to-Background Ratio (TBR)Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Assessment of target-to-background ratio for evaluating SSTR2-expressing tissue contrast across different scan durations, reconstruction techniques, and AI-enhanced image reconstructions. Unit of Measure: Ratio (unitless numeric ratio)
- Qualitative Image Quality Score (Likert Scale)Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Independent qualitative evaluation of overall image quality, lesion detectability, image noise, and artifacts by nuclear medicine physicians, assessed using a 5-point Likert scale. Unit of Measure: Score on Likert Scale (1-5; 1 = worst, 5 = best)
- Inter-reader Agreement (Weighted Kappa Statistics)Evaluated annually (once per year), based on pooled images acquired during the preceding 12-month period.
Measurement of agreement among readers evaluating qualitative image quality scores, analyzed using weighted kappa statistics. Unit of Measure: Weighted kappa statistic (numeric value ranging from 0 to 1, 0 = no agreement, 1 = perfect agreement)