FOA on Sit to Stand in Individuals Post Chronic Stroke
At a glance
Conditions
NCT07460804
Where you'd take part
This study runs at 1 site. They're the same protocol — you choose where, and that choice sets who your contact draft is addressed to.
Western Carolina University
Cullowhee, North Carolinastudy coordinator listed
Recruiting
Sites open and close at different times, so the status above is per site — it can differ from the study's overall status.
Who to contact
Opens a ready-to-send draft in your own email app — review before sending.
Want this trial checked against your situation?
Add a private profile and we'll compare every criterion below against your situation — and tell you which ones are met, uncertain, or excluding.
Inclusion
Exclusion
What this trial measures
- Center of pressure under their feetBaseline
HR Pressure mat - Symmetry under the feet will be measured using a 61.26 X 58.72 cm pedobarograph with a 48.8 X 44.7 cm active sensing area during the sit to stand transition. The mat has 3.9 sensors/cm2 with a 185 Hz scanning rate. The mat will be calibrated prior to the start of the study.
- Center of pressure under their feetAcquisition (one 1 hour training)
HR Pressure mat - Symmetry under the feet will be measured using a 61.26 X 58.72 cm pedobarograph with a 48.8 X 44.7 cm active sensing area during the sit to stand transition. The mat has 3.9 sensors/cm2 with a 185 Hz scanning rate. The mat will be calibrated prior to the start of the study.
- Center of pressure under their feetImmediate Post (5 minutes after acquisition training)
HR Pressure mat - Symmetry under the feet will be measured using a 61.26 X 58.72 cm pedobarograph with a 48.8 X 44.7 cm active sensing area during the sit to stand transition. The mat has 3.9 sensors/cm2 with a 185 Hz scanning rate. The mat will be calibrated prior to the start of the study.
- Center of pressure under their feetLong term (one hour after acquisition/training)
HR Pressure mat - Symmetry under the feet will be measured using a 61.26 X 58.72 cm pedobarograph with a 48.8 X 44.7 cm active sensing area during the sit to stand transition. The mat has 3.9 sensors/cm2 with a 185 Hz scanning rate. The mat will be calibrated prior to the start of the study.
- Trunk alignmentBaseline
IMU sensors -One Delsys inertial measurement units (IMUs) will be placed on the T1 spinous process to capture vertical trunk alignment throughout sit to stand.
- Trunk alignmentAcquisition (one 1 hour training)
IMU sensors -One Delsys inertial measurement units (IMUs) will be placed on the T1 spinous process to capture vertical trunk alignment throughout sit to stand.
- Trunk alignmentImmediate Post (5 minutes after acquisition training)
IMU sensors -One Delsys inertial measurement units (IMUs) will be placed on the T1 spinous process to capture vertical trunk alignment throughout sit to stand.
- Trunk alignmentLong term (one hour after training)
IMU sensors -One Delsys inertial measurement units (IMUs) will be placed on the T1 spinous process to capture vertical trunk alignment throughout sit to stand.
- Post Manipulation QuestionnaireLong term (after all measures completed 1 hour after training)
To establish whether participants were thinking about what they were instructed, all individuals were given a post manipulation questionnaire after the 1-hour post training retention testing for each condition. Participants were asked to rate how much they were thinking about "a target that is outside of your body," "how you move your body (e.g. shoulders, hips, trunk)," and about "something else." They responded on a Likert scale with 5 representing very much so and 1 to represent not at all.